INTRODUCTION CW-3000 Series is professional cooling machine referring to international advanced thermolysis cooling system design, suitable for small water-cooled cooling devices requested machinery. 1. Specific disconnection alarm security protection. 2. Hermetic type water tank, water is available for a long time used. 3. Real-time temperature monitoring, accurate knowledge of heating devices working condition. 4. Professional air-cooled forced radiator with strong heat dissipating capacity and difficult to be blocked up. 5. Equipped with alarm output port to protect sensitive components quickly. 6. High cost performance, low failure rate. 7. There are several options of power supply, complete in specifications.
CAUTION 1. It is strictly forbidden to plug and run the cooler without feeding water. 2. Cooler should be placed in a well-ventilated, dry environment place and away from heat sources. Please keep at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 10cm between obstructions and air inlets of two sides. 3. The cooling water must be drained if the cooler is out of use for long time or before being transported. 4. To protect laser tubes , the radiator fan of cooler will suspend to work when water temperature is lower ( about 10ć ć ) , and it will restart to run when water temperature rises to higher ( about 20 ć).
2
CW-3000 USER MANUAL
Details 1ˊ ˊShape and parts name FRONT
POWER SW TEMPERATURE DISPLAY SYSTEM ALARM INDICATOR RUNNING INDICATOR
BACK
INJECTION PORT ALARM SIGNAL OUTPUT TERMINAL
POWER SOCKET (WITH FUSE) OUTLET INLET RADIATOR FAN
OUTFALL
3
CW-3000 USER MANUAL
2. The first installation
1. 2. 3. 4. 5.
It is very simple to install this industrial cooling machine. The first time installation of the new machine can be carried out by following steps. Open the package to check if the machine is intact and all the necessary accessories are completed. Open the injection port, then add cooling water. According to system conditions, connect the water inlet and outlet pipe well. Plug in power, turn on the power switch. (Do not allow the water overflow) Check the water level of the water tank again. (It should be 80-150cm from the surface of water to the injection port)
3. Alarm description Causes of the cooling water circulation loop alarm and the working condition table.
Display Condition
Green light
Red light
Buzzer
out
out
H1ǃ ǃH2
H1ǃH3
Normal
On
Off
No voice
Off
On
Water stops up
Off
On
Voice
On
Off
Surpasses 60ć
Off
On
Voice
On
Off
Pump breakdown
Off
On
Voice
On
Off
Water alarm
Off
On
Voice
On
Off
Faulted circuit
On
Off
Power outage
On
Off
Note: The flow alarm port connects to the normally open relay and normally closed relay contacts, requiring operating current to be less than 5A, working voltage less than 300V.
4
CW-3000 USER MANUAL
4. Maintenance 1. To ensure good heat dissipating, please open the lid to clean the dirt after the cooler used in long-term. 2. Working in cold north area, it is better to use noncorrosive antifreeze fluid.
SPECIFICATIONS Model
CW-3000AG
CW-3000DG
CW-3000AF
CW-3000DF
CW-3000AK
CW-3000DK
Voltages
AC220~240V
AC100~120V
AC220~240V
AC100~120V
AC220~240V
AC100~120V
0.5A
1.0A
Frequency Current
50/60Hz 0.45A
0.9A
0.45A
0.9A
50W/ e C
Cooling capacity
60W/ eC 9L
Inlet and
Outside dimensions
Inside dimensions
Inside dimensions
outlet hold
10mm brass connector
8mm speedy connector
6mm speedy connector
Max. pumping 10 M
70 M
N.W
9.5Kg
12Kg
G.W
12Kg
14.5Kg
lift
Dimensions
47X27X37cm(LxWxH)
Packing 59X39X48cm(LxWxH)
dimensions
5
CW-3000 USER MANUAL
SIMPIE TROUBLESHOOTING Failure
Fault cause
Approach
Power cord is not plugged in place
Plug the power cord in place
fuse burnt-out
Replace the fuse inside the power interface which is in the back of machine
Flow alarm (panel red light) with water pipe directly connect to the outlet, inlet, there is no water flow
Water level in water tank is too low
Feed water and check the pipe leakage
When used with the device, flow alarm (panel red light), but a direct connection with the pipe outlet and inlet, there is water flowing but not alarming
Blockage in circulating water pipeline
Check circulating water pipeline
Chiller of poor ventilation
To improve the ventilation
Excessive heat load
Reduce the heat load or to use other models
The water temperature below 20 degrees
A normal phenomenon, no processing
Water drop in electric circuit
Natural drying or drying off cap
Damaged pumps dry transfer
To replace or repair water pumps,prohibited anhydrous boot
The injection port is not open
Open the injection port
Machine turned on but unelectrified
Ultra-high temperature
A normal boot, but the fan does not work Switch on with alarming after adding water or changing water
Slow
outfall drainage
PACKING LIST 1. 2. 3. 4.
Machine 1pc,user manual 1pc. Power cord 1pc, connection hose 1pc,sealed hoop 2pcs. Spare fuse for 250V/2A 1pc. (Held in the spare fuseholder of power socket.) An alarm signal output plug.
CAUTION: The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction,children being supervised not to play with the appliance!